6 Hole Fiber Optic Dental High Speed Handpiece Kavo Stype Ceramic Bearings
Quick Type Air Turbine
High Speed Turbine Handpiece with Fiber Optic,Torque Head,Triple Water Spray,Anti-retractive Valves,fiber optic dental handpiece
Fiber optic handpiece Features:
Torque type turbine head
- Speed 300,000-420,000rpm
- Lighting: 25,000LUX fiber lightness create perfect light for operation area
- Bearing: German Ceramic Bearings
- Safe: Stable operation effect, clamping force more than 4kg, very safe for the operation
- Hygiene: KV handpiece can be autoclavable at 135℃ and cleaned by ultrasonic cleaner
- Anti-retractive valves: KV Special design for the hygiene, the anti-retractive valve can stop the powder and dirty enter into the turbine head
- Cooling: Triple spray, water mixed spray, to have best spray cooling to guarantee the great cooling during operation
- Applicable to the ISO international standard 4 holes or 6 holes phone lines
Technical data:
Product name | Fiber optic dental handpiece |
Drive air pressure | 0.25-0.3Mpa |
Water pressure | 0.2Mpa |
Water pressure | 198Kpa(2kg) |
Light brightness | 25500lux |
Power | 22W |
Rotation speed | 350,000~420,000rpm(Standard head), 300,000-350,000rpm(big head) |
Head height | 13.0mm(standard head)/ 13.1mm (big head) |
Head diameter | Φ11mm standard, 12.7mm big |
Chuck type | Push button |
Clamping force | 22N~34N |
Torque force | 0.1N·cm |
Bur Applicable | Φ1.59mm-Φ1.6mm*21mm-23mm(diameter*length) |
Noise | ≤60DB |
push button to take burs |
Kavo type connection |
FIber otpic light Triple water spraying German cartridge |
After each patient use , maintenance should be done as follows:
1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate
2. Use a metal needle to clean the spray holes and fumaroles
Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle
3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes )
4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom
5. The handpiece with quick connector combination ( first determine the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie )
7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain
8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization